Journal of Prosthetic Dentistry
Volume 104, Issue 2 , Pages 114-121, August 2010

Effects of investment type and casting system on permeability and castability of CP titanium

  • Fazal Reza, BDS, PhD

      Affiliations

    • Former PhD student, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan; currently, Senior Lecturer, School of Dental Sciences, Universiti Sains Malaysia, Kelantan, Malaysia
  • ,
  • Hidekazu Takahashi, DDS, PhD

      Affiliations

    • Associate Professor and Director, Advanced Biomaterials, Department of Restorative Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
    • Corresponding Author InformationCorresponding author: Dr Hidekazu Takahashi, Advanced Biomaterials, Department of, Restorative Sciences, Graduate School of Medical and Dental, Sciences, Tokyo Medical and Dental University, Yushima 1-5-45, Bunkyo-ku, Tokyo 113-8549, JAPAN, Fax: +81-3-5803-0191
  • ,
  • Naohiko Iwasaki, RDT, PhD

      Affiliations

    • Research Associate, Advanced Biomaterials, Department of Restorative Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
  • ,
  • Yukimichi Tamaki, DDS, PhD

      Affiliations

    • Associate Professor, Oral Biomaterials and Technology, Showa University School of Dentistry, Kelantan, Malaysia

Statement of problem

Several factors, such as casting systems and investment properties, are important to obtain a sound titanium casting. Although various casting systems and investments for titanium are commercially available, their effects on CP titanium castability are not clear.

Purpose

The purpose of this study was to determine permeability of investments and to evaluate the effects of investment type and casting system on titanium castability.

Material and methods

Three investments for titanium (experimental gypsum-bonded investment, Selevest CB, and Speed Titan) and 4 titanium casting systems (Cyclarc, Ti-Cascom, Vulcan T, and Ticast Super R) were used. Permeability was measured using a flow meter and argon gas at 0.1, 0.2, and 0.3 MPa. Castability was calculated as the percentage of reproduced holes compared to a perforated wax pattern. Data for castability and permeability were analyzed separately with 2-way ANOVA and the Tukey HSD test (α=.05).

Results

The ANOVA for permeability and castability showed significant interaction (P<.001 and P=.004, respectively). Differences in permeability among the 3 investments increased with a higher gas pressure. Permeability of the experimental investment at each pressure level was significantly greater than that of the other investments, except for Speed Titan at 0.1 MPa (P<.05). The permeability of Selevest CB at each pressure level was significantly less than that of the other investments (P<.05). Cyclarc and Ti-Cascom specimens were not significantly different, in terms of castability, using the investments evaluated, but castability of Vulcan T and Ticast specimens varied significantly by the investment used (P<.05).

Conclusions

Within the limitations of this study, investment type, pressure level, and their combinations influenced permeability. Castability of titanium was influenced by investment type, casting system, and their combinations. The investment with the highest permeability did not demonstrate the best result for castability.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-3913(10)60103-5

doi:10.1016/S0022-3913(10)60103-5

Journal of Prosthetic Dentistry
Volume 104, Issue 2 , Pages 114-121, August 2010