An evaluation of the effects of handpiece speed, abrasive characteristics, and polishing load on the flexural strength of polished ceramics

  • Rohana Ahmad, BDS, MSD

      Affiliations

    • Senior Lecturer, Department of Conservative Dentistry, Faculty of Dentistry, University Malaya
  • ,
  • Steven M. Morgano, DMD

      Affiliations

    • Professor and Director, Division of Postdoctoral Prosthodontics, Department of Restorative Sciences/Biomaterials, Boston University Goldman School of Dental Medicine
    • Corresponding Author InformationReprint requests to: Dr Steven M. Morgano, Boston University, School of Dental Medicine, Division of Postdoctoral Prosthodontics, 100 East Newton St, Rm G 219, Boston, MA 02118 Fax: 617-638-5434
  • ,
  • Benjamin M. Wu, DDS, PhD

      Affiliations

    • Assistant Professor, Hospital Dentistry, Advanced Prosthodontics, Biomedical Engineering, University of California, Los Angeles School of Dentistry
  • ,
  • Russell A. Giordano, DMD, DMSc

      Affiliations

    • Associate Professor and Director, Division of Biomaterials, Department of Restorative Sciences/Biomaterials, Boston University Goldman School of Dental Medicine

Faculty of Dentistry, University Malaya, Kuala Lumpur, Malaysia; Boston University Goldman School of Dental Medicine, Boston, Mass; University of California, Los Angeles School of Dentistry, Los Angeles, Calif

Statement of problem

Many studies on the strengthening effects of grinding and polishing, as well as heat treatment on ceramics, are not well standardized or use commercially available industrial polishing systems. The reported effectiveness of these strengthening mechanisms on ceramics may not be applicable to clinical dentistry.

Purpose

The purpose of this study was to evaluate the effects of controlled polishing on the flexural strength of dental ceramics by using a custom-made machine that applied standardized loads and speeds that coincided with the mean loads and speeds used by experienced prosthodontists.

Material and methods

A total of 140 aluminous dental ceramic bar-shaped specimens (Vitadur Alpha Enamel) measuring 1.5 × 2.0 × 25 mm were fabricated and divided into 12 groups (for most groups, n=10). Specimens were untreated, polished with different polishing systems, polished at different speeds, ground and autoglazed, polished and autoglazed, autoglazed and polished, polished with loose (paste) and bonded abrasives, or overglazed. Simulated clinical polishing was performed on the ceramic specimens by using a customized polishing apparatus that allowed independent control over the relevant polishing parameters (abrasive hardness, applied load, linear speed, rotational velocity, and wheel stiffness). Flexural strength (MPa) was measured with a 4-point bending test, and subjective surface roughness was assessed with scanning electron microscopy. Autoglazing was performed at various stages of the polishing sequence to determine the effects of polishing on surface stresses. Mean values, standard deviations, independent-sample t tests, 1-way and 2-way analyses of variance, Dunnett t tests and Kruskal-Wallis tests were applied to the data (α=.05).

Results

Under a clinical load of 0.6 N for a coarse polishing wheel, 1.0 N for a medium polishing wheel, and 1.3 N for a fine polishing wheel, a linear speed of 499 mm/min, and a rotational velocity of 10,000 rpm, the use of clinical polishing instruments did not affect the flexural strength of the aluminous ceramics studied (P=.274). At higher rotational velocity (20,000 rpm), specimens polished with the diamond polishing system produced statistically weaker specimens compared with those that had been polished at 10,000 rpm (P=.019). Autoglazing treatment of the diamond-polished specimens did not reverse the strength degradation (P=.125). Conversely, diamond polishing of the autoglazed specimens resulted in significant flexural strength reduction (P=.029). Fine-diamond-bonded abrasive significantly reduced flexural strength (P=.025).

Conclusions

Simulated clinical polishing at 10,000 rpm did not appear to substantially strengthen or weaken the ceramic specimens. Polishing at 20,000 rpm reduced flexural strength of the ceramic bars.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-3913(05)00440-3

doi:10.1016/j.prosdent.2005.08.014

Journal of Prosthetic Dentistry
Volume 94, Issue 5 , Pages 421-429, November 2005