Journal of Prosthetic Dentistry
Volume 93, Issue 5 , Pages 459-466, May 2005

The effect of a layer of resin luting agent on the biaxial flexure strength of two all-ceramic systems

  • Roland P. Pagniano Jr., DDS, MS

      Affiliations

    • Private practice, Dublin, Ohio
    • Corresponding Author InformationReprint requests to: Dr Roland Pagniano and Associates, Inc, 6805 Avery-Muirfield Dr., Suite 201, Dublin, OH 43016, Fax: 614-932-9451
  • ,
  • Robert R. Seghi, DDS, MS

      Affiliations

    • Professor, Department of Restorative and Prosthetic Dentistry
  • ,
  • Stephen F. Rosenstiel, BDS, MSD

      Affiliations

    • Professor, Department of Restorative and Prosthetic Dentistry
  • ,
  • Rentong Wang, PhD

      Affiliations

    • Graduate Research Assistant, Department of Mechanical Engineering
  • ,
  • Noriko Katsube, PhD

      Affiliations

    • Professor, Department of Mechanical Engineering

The Ohio State University, College of Dentistry, Department of Restorative and Prosthetic Dentistry, and College of Engineering, Department of Mechanical Engineering, Columbus, Ohio

Statement of problem

The influence of a layer of resin luting agent on the longevity of glass-ceramic crowns has been demonstrated in some laboratory and clinical studies. The mechanisms of glass-ceramic crown failure and the influence of the resin luting agent layer are still not clearly understood.

Purpose

The objectives of this study were to examine the difference in biaxial flexure strength between 2 glass-ceramic dental materials and to examine the influence of a layer of resin luting agent on the characteristic strength of these materials.

Material and methods

Thirty-seven disks, 15 mm × 1.5 mm, each of IPS Empress and IPS Empress2, were fabricated according to the manufacturer's recommendations. The surface of each disk underwent acid etching and silanation. The disks from each group were arbitrarily divided into 2 subgroups. One subgroup of each material type was selected to receive a thin (approximately 0.1 mm) layer of resin luting agent (Nexus 2), whereas the other subgroups remained unaltered. Each disk was loaded, with the treated surface down, using a ball-on-ring biaxial configuration in a universal testing machine. The failure loads (N) were recorded, and the biaxial flexure strength for each disk was calculated. Characteristic Weibull parameters and a ±95% confidence interval were determined. A 2-way analysis of variance (α=.05) on transformed fracture strength data was used to determine significant differences between groups.

Results

The Weibull characteristic strength of IPS Empress2 (213 MPa) was 75% higher than IPS Empress (122 MPa). The results also show that the application of a thin layer of resin luting agent significantly increased (P<.001) the characteristic strength of both IPS Empress and IPS Empress2 by 45.6% and 47.6%, respectively. The higher strength of the resin-coated specimens cannot be explained in terms of standard fracture mechanics alone.

Conclusion

Results suggested that IPS Empress had significantly lower characteristic strength than IPS Empress2. A relatively thin layer of resin luting agent bonded to both IPS Empress and IPS Empress2 significantly increased the characteristic strength of the ceramics.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0022-3913(05)00101-0

doi:10.1016/j.prosdent.2005.02.012

Journal of Prosthetic Dentistry
Volume 93, Issue 5 , Pages 459-466, May 2005