Journal of Prosthetic Dentistry
Volume 93, Issue 2 , Pages 153-157, February 2005

Relative wear of flowable and highly filled composite

  • Nancy L. Clelland, DMD, MSD

      Affiliations

    • Associate Professor, Department of Restorative and Prosthetic Dentistry
    • Corresponding Author InformationReprint requests to: Dr Nancy L. Clelland, The Ohio State University, College of Dentistry, 305 W 12th Ave, #191, Columbus, OH 3218-2357, Fax: 614 292-9422.
  • ,
  • Matthew P. Pagnotto

      Affiliations

    • Former Dental Student
  • ,
  • Ronald E. Kerby, DDS

      Affiliations

    • Associate Professor, Department of Restorative and Prosthetic Dentistry
  • ,
  • Robert R. Seghi, DDS, MS

      Affiliations

    • Professor, Department of Restorative and Prosthetic Dentistry

The Ohio State University, College of Dentistry, Columbus, Ohio

Statement of problem

By decreasing the proportion of filler, flowable composites are easy to adapt to small cavity preparations. However, the wear resistance of flowable composites is a clinical concern, as improved wear has been related to increased filler percentage.

Purpose

The purpose of this study was to compare wear for flowable composites and comparable heavily filled materials.

Material and methods

Wear by attrition and abrasion (μm) of microfilled flowable (Heliomolar Flow) and heavily filled microfill (Heliomolar HB) was measured and compared to a microhybrid flowable (Tetric Flow) and a heavily filled microhybrid (Tetric HB). There were 5 specimens, 2 mm thick and 15 mm in diameter, in each group. The Oregon Health Sciences University oral wear simulator was used to produce abrasive wear and attrition for all specimens. Abrasion and attrition of the substrates were measured using a profilometer. Data were subjected to a 3-way analysis of variance for the 3 main factors: composite type, filler load, and wear type (α=.05)

Results

Composite wear rates were significantly influenced (P<.01) by both the type of wear and the filler amount. Abrasive wear occurred less than wear by attrition, and the heavily filled composites experienced less wear than the flowable composites.

Conclusions

Results of this in vitro study suggest that highly filled microhybrid composites may have greater wear resistance for contact-supporting posterior restorations. However, in small noncontact restorations where longevity may be dictated by abrasion, flowable microfilled resins may be adequate.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Supported by the Ohio State University College of Dentistry Summer Research Program.

PII: S0022-3913(04)00737-1

doi:10.1016/j.prosdent.2004.11.006

Journal of Prosthetic Dentistry
Volume 93, Issue 2 , Pages 153-157, February 2005