Journal of Prosthetic Dentistry
Volume 90, Issue 4 , Pages 354-364, October 2003

The effect of surface moisture on detail reproduction of elastomeric impressions

  • Glen H Johnson, DDS, MS

      Affiliations

    • Professor, Department of Restorative Dentistry, University of Washington, Seattle, Wash, USA
    • Corresponding Author InformationReprint requests to: Dr Glen H. Johnson, Department of Restorative Dentistry, Box 357456, University of Washington, Seattle, WA 98195-7456, USA, Fax. 206-543-7783
  • ,
  • Xavier Lepe, DDS, MS

      Affiliations

    • Associate Professor, Department of Restorative Dentistry, University of Washington, Seattle, Wash, USA
  • ,
  • Tar Chee Aw, DDS, MS

      Affiliations

    • Assistant Professor, Department of Restorative Dentistry, University of Washington, Seattle, Wash, USA

Abstract 

Statement of problem

Monophase and dual-viscosity impression techniques are available with little knowledge of which one might render better quality under wet and dry surface conditions.

Purpose

The purpose of this study was to determine whether type of material, viscosity selection, and presence of moisture affect detail reproduction of elastomeric impressions.

Material and methods

Single-viscosity systems were polyether (Impregum Penta) and vinyl polysiloxanes (President MonoBody, Extrude MPV, and Aquasil). Dual-viscosity systems included polyether (Impregum Penta/Permadyne Garant) and vinyl polysiloxanes (Dimension Penta H/Dimension Garant L, Extrude Extra/Extrude Wash, and Aquasil/Aquasil LV). Impressions were made of a surface analyzer calibration standard possessing a uniform “saw-tooth” pattern with a mean roughness (Ra) of 2.87 μm, which was one fourth of the peak-to-valley height. Each of the 8 impression groups was subjected to dry (control) and wet conditions. The wet condition consisted of 3 mL of distilled water applied to the surface of the standard but allowed to escape during the procedure. Eighty impressions were made, 5 for each test group. After setting, the surface of each impression was scanned at 5 locations using a Surfanalyzer 4000. A 3-factor ANOVA and Student-Newman-Kuels test were used to analyze the data (α=.05).

Results

There were significant differences between polyether and vinyl polysiloxane materials, dual and monophase techniques, and the 2 surface conditions (P<.05). Cross-product interactions were not significant, allowing comparison of mean values for each factor. The mean Ra for single viscosity was 2.21 μm versus 1.67 μm for dual viscosity; polyether was 2.12 μm versus 1.89 μm for addition silicone; and under dry conditions, the mean was 2.04 μm versus 1.86 μm for wet conditions.

Conclusion

Single-viscosity systems reproduced the standard saw-tooth pattern better than the dual-viscosity systems, as did polyether impression materials compared to addition silicones. Moisture led to a lower Ra or less detail compared to dry conditions.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 This project was supported in part by 3M ESPE, St. Paul, Minn and Seefeld, Germany.

PII: S0022-3913(03)00429-3

doi:10.1016/S0022-3913(03)00429-3

Journal of Prosthetic Dentistry
Volume 90, Issue 4 , Pages 354-364, October 2003