A positioning device for computed tomography: A clinical report☆☆★★♢♢

Dental School, University of Chieti, Chieti, Italy

Abstract 

This clinical report describes a device (Centrascan) used to assist in the correct alignment of the patient's head during computed tomography (CT) assessment of a proposed implant site. To obtain the desired anatomic detail, CT requires precise alignment of the axial images at right angles to the long axis of the proposed implant. This clinical report compared the anatomic morphology of a projected implant site derived from axial images provided by DentaScan software analysis of the CT scan acquisition. Images from a conventional scan, with the patient's head aligned along the frontal plane (perpendicular to the Frankfort plane) and along the sagittal plane (coinciding with either the cortical bone of the hard palate or the inferior border of the mandible), were compared with images acquired by use of the Centrascan device. The two scans differed substantially. In particular, the cross-sectional images obtained by the conventional procedure showed a distorted anatomy; conversely, the images obtained by the Centrascan procedure showed a better reproduction of the examined area. The Centrascan device seemed to help the radiologist achieve a more correct alignment of the patient's head during CT scan acquisition. Further studies are necessary to fully explore the relative technical merits of the Centrascan device. (J Prosthet Dent 2003;89:123-6.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Reprint requests to: Dr Giuseppe Varvara, Dipartimento di Scienze Odontostomatologiche, Universita di Chieti, Via dei Vestini 31, 66100 Chieti, ITALY, Fax: 0039-0871-3554072, E-mail: g.varvara@tin.it

☆☆ aProfessor, Department of Odontostomatology Sciences.

 bProfessor, Department of Odontostomatology Sciences.

★★ cProfessor, Department of Odontostomatology Sciences.

 dResearch Fellow, Department of Odontostomatology Sciences.

♢♢ eProfessor and Chairman, Department of Odontostomatology Sciences.

 0022-3913/2003/$30.00 + 0

PII: S0022-3913(03)00065-9

doi:10.1067/mpr.2002.83

Journal of Prosthetic Dentistry
Volume 89, Issue 2 , Pages 123-126, February 2003