Journal of Prosthetic Dentistry
Volume 87, Issue 1 , Pages 23-29, January 2002

Accuracy of 3 conceptually different die systems used for implant casts☆☆★★

College of Dentistry, The Ohio State University, Columbus, Ohio, and Faculty of Dentistry, University of Toronto, Ontario, Canada

Abstract 

Statement of Problem. Given that meticulous implant prosthodontic procedures are recommended to obtain the best possible intraoral fit, the die systems used for multi-implant casts warrant further investigation. Purpose. The purpose of this in vitro study was to compare the accuracy of implant casts fabricated from 3 conceptually different die systems at the solid, sectioned, and repeated stages. Material and Methods. Thirty direct transfer implant impressions were made of the master cast with a polyether impression material. Ten experimental implant casts were fabricated for each of the 3 different die systems tested: double-pour (Pindex), plastic base (DVA), and die tray (KO Tray). The solid experimental casts were sectioned and then removed from the die system 30 times. Linear distances between steel balls placed on each abutment replica were measured with a traveling microscope to determine the accuracy of the experimental casts at different stages. Data were analyzed with repeated-measures analysis of variance (α=.05) and the post hoc Ryan-Einot-Gabriel-Welsch multiple-range test (REGWQ). Results. Repeated-measures analysis of variance revealed a significant interaction between the die systems and different stages (P=.0432). REGWQ showed the die tray system to be significantly more accurate at the solid than at the sectioned and repeated stages. The die tray system was significantly less accurate than the double-pour and plastic base systems at the sectioned stage. Conclusion. Within the limitations of this study, the use of a double-pour or plastic base die system is recommended when sectioned dies are needed for a multi-implant-retained prosthesis. (J Prosthet Dent 2002;87:23-9.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 This project was supported in part by The Ohio State University College of Dentistry Student Summer Research Program (NIH DE 07155-13 grant) and presented in part at the International Association of Dental Research annual session, April 2000, Washington, DC.

☆☆ aAssistant Professor, Section of Restorative Dentistry, Prosthodontics and Endodontics, The Ohio State University.

 bAssistant Professor, Department of Prosthodontics, University of Toronto; Head of Maxillofacial Prosthetics, University Health Network-Princess Margaret Hospital.

★★ cThird-year dental student, The Ohio State University.

 Reprint requests to: Dr Alvin G. Wee, Section of Restorative Dentistry, Prosthodontics and Endodontics, The Ohio State University, Postle Hall, 305 W 12th Ave Columbus, OH 43210-1241, Fax: (614)292-9422 E-mail: Wee.12@osu.edu

PII: S0022-3913(02)27584-8

doi:10.1067/mpr.2002.121110

Journal of Prosthetic Dentistry
Volume 87, Issue 1 , Pages 23-29, January 2002