Effect of tissue conditioners on the dynamic viscoelastic properties of a heat-polymerized denture base☆☆★★

Presented at the 103rd Scientific Meeting of the Japan Prosthodontic Society, Ohmiya, Japan, June 2000.

Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan

Abstract 

Statement of Problem. Little is known about the influence of tissue conditioners on physical property alteration of denture base resins. Purpose. This study evaluated the influence of a variety of commercial tissue conditioners on alteration of viscoelastic properties of a heat-polymerized denture base acrylic resin. Material and Methods. Four tissue conditioners and 1 heat-polymerized denture base acrylic resin were used. In one experiment, acrylic resin specimens (1.0-mm thick) were immersed in the liquid component of tissue conditioners for 36 hours. In another experiment, tissue conditioners were applied to acrylic resin specimens (0.5-mm and 1.0-mm thick) in a 2-mm layer; the specimens then were immersed in distilled water for 1 week. Control specimens for both groups had no lining and were immersed in distilled water for 36 hours and 1 week, respectively. Dynamic viscoelastic properties of the acrylic resin specimens were measured at 37°C with an automatic viscoelastometer. Tensile storage modulus (E′), tensile loss modulus (E″), and loss tangent (tan δ) were determined at 1 Hz. These parameters were compared with analysis of variance and the Dunnett test at a predetermined significance level of .05. All statistical comparisons were made with reference to the control group and not to each other. Results. Only the liquid of Hydro-Cast significantly reduced E′ and increased tan δ of the acrylic resin (P<.05). Acrylic resin specimens 0.5-mm thick and lined with tissue conditioners tended to have lower E′ and higher tan δ than the control. However, only Hydro-Cast and SR-Ivoseal significantly decreased E′, and only Hydro-Cast raised tan δ of the acrylic resin (P<.05). No significant difference was found among the E″ values. The tissue conditioners did not affect E′, E″, or tan δ of acrylic resin specimens 1.0-mm thick. Conclusion. Within the limitations of this study, some tissue conditioners significantly plasticized the denture base acrylic resin 0.5-mm thick. However, when the acrylic resin was 1.0-mm thick, no plasticization by the tissue conditioners was noted. (J Prosthet Dent 2002;88:409-14.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Reprint request to: Dr Hiroshi Murata, Department of Prosthetic Dentistry, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi Minami-Ku, Hiroshima 734-8553, JAPAN, Phone: (81)82-257-5682, Fax: (81)82-257-5684, E-mail: hmurata@hiroshima-u.ac.jp

☆☆ aInstructor, Department of Prosthetic Dentistry.

 bResident, Department of Prosthetic Dentistry.

★★ cGraduate student, Department of Prosthetic Dentistry.

 dProfessor and Chair, Department of Prosthetic Dentistry.

PII: S0022-3913(02)00233-0

doi:10.1067/mpr.2002.128101

Journal of Prosthetic Dentistry
Volume 88, Issue 4 , Pages 409-414, October 2002