Journal of Prosthetic Dentistry
Volume 87, Issue 6 , Pages 603-612, June 2002

Application of a 3-dimensional measurement system to complete denture impressions☆☆★★

Rene Descartes University, and Ecole Nationale Superieure d'Arts et Metiers, Paris, France

Abstract 

Statement of Problem. Little is known about tissue displacement at the tissue/denture base interface during impression making. Purpose. This study used a new 3-dimensional measurement system to analyze and compare 2 complete denture reline impression techniques (1 occluding and 1 digital) to determine which resulted in less displacement of the tissue/denture base interface during impression making. Material and Methods. The experiment included 10 completely edentulous subjects. For each subject, 3 mandibular casts were obtained: (1) a reference cast of the existing denture base, (2) a cast made with an occluding reline impression technique, and (3) a cast made with a digital reline impression technique. With the use of an optical 3-dimensional measurement system, the corresponding casts in a common coordinate system were analyzed geometrically. For each cast, the coordinates of the barycentric point and the high point were determined. For the same subject, the differences between the coordinates of the barycentric points of the 3 casts were calculated 2-by-2. The same calculation was performed for the high points. To determine whether these differences, which represent the displacements of the barycentric points and the high points, were statistically significant, the Wilcoxon signed-rank test for paired group comparisons was applied (P<.05). Cartographic differences among the casts from the same subject also were compared. Results. The uncertainty of measurement for the location of the barycentric and highest point was ±57 μm. The uncertainty in the differences among the cartographic displays was ±0.1 mm. Vertically, the mean distance that separated the barycentric points obtained with the 2 impression methods was 0.04 mm. Cartography data showed that the greatest dimensional differences between the 2 impression techniques (minimum 0.25 mm; maximum 1.5 mm) were located near the retromolar pad and along the lingual flange. Conclusion. Within the limitations of this 3-dimensional in vivo study, displacement of the tissue/denture base interface was essentially equivalent with the use of an occluding and a digital mandibular impression technique. (J Prosthet Dent 2002;87:603-12.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 aLecturer, Department of Prosthetic Dentistry, Rene Descartes University.

☆☆ bLecturer, Ecole Nationale Superieure d'Arts et Metiers.

 cSenior Lecturer, Department of Anatomy, Rene Descartes University.

★★ Reprint requests to: Dr C. Rignon-Bret, Departement de Prothese, Universite Rene Descartes, 1, rue Maurice Arnoux, 92120 Montrouge, France, Fax: (33)01-4874-7427, E-mail: rignon-bret@odontologie.univ-paris5.fr

PII: S0022-3913(02)00020-3

doi:10.1067/mpr.2002.124204

Journal of Prosthetic Dentistry
Volume 87, Issue 6 , Pages 603-612, June 2002