Journal of Prosthetic Dentistry
Volume 86, Issue 5 , Pages 526-531, November 2001

Shear bond strengths of 2 intraoral porcelain repair systems to porcelain or metal substrates☆☆★★

College of Dentistry, University of Iowa, Iowa City, Iowa

Abstract 

Statement of Problem. When clinical fractures of the ceramic veneer on ceramometal can be repaired, the need for remake can be eliminated or postponed. A number of ceramic repair materials are available; bond strength data would be useful for predicting the success of a given repair system. Purpose. This in vitro study evaluated shear bond strengths of 2 porcelain repair systems intended for intraoral bonding of resin to porcelain and metal. Material and Methods. Sixty cylindrical specimens were fabricated with feldspathic porcelain and/or a high noble alloy: 20 porcelain (P), 20 porcelain and metal (PM), and 20 metal (M). Specimens were divided into subgroups of 10, and resin composite cylinders were bonded with 1 of 2 systems: CoJet-System (CJ) or Ceramic Repair (CR). Bonded specimens were stored in 37°C distilled water for 24 hours before being thermocycled at 5°C to 55°C for 300 cycles with a 30-second dwell time. The specimens then were stored for an additional 8 days before being subjected to shear force in a universal testing machine at a crosshead speed of 5 mm/min. Stress at failure was calculated in MPa, and mode of failure was recorded. Analysis of variance (ANOVA) was applied to the data. Comparisons between substrates were made with the Duncan multiple range test (P <.05), and differences between the 2 repair systems within like substrate groups were examined with the Student t test. Results. Bonding groups exhibited the following values in megapascals: PM-CR = 19.3 ± 4.1; PM-CJ = 25.0 ± 3.1; M-CR = 14.3 ± 4.9; M-CJ = 23.0 ± 2.3; P-CR = 18.3 ± 4.2; P-CJ = 22.4 ± 5.6. The ANOVA results showed significant differences between the CJ and CR groups. The Student t test revealed that the mean data for the CJ groups were significantly higher than for the CR groups (P <.05). The Duncan multiple range test demonstrated significant differences between the PM and M groups (P <.05) for the CR system only. Conclusion. Under the conditions of this study, CJ achieved significantly higher bond strengths to PM and M substrates. Significant differences in strength were found between PM and M, but only within the CR system. (J Prosthet Dent 2001;86:526-31.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 aAssistant Professor, Department of Family Dentistry.

☆☆ bAssociate Professor, Department of Family Dentistry.

 cAssistant Professor, Department of Family Dentistry.

★★ Reprint requests to: Dr Debra R. Haselton, Department of Family Dentistry, University of Iowa College of Dentistry, Iowa City, IA 52242, Fax: (319)335-9683, E-mail: debra-haselton@uiowa.edu

PII: S0022-3913(01)07589-8

doi:10.1067/mpr.2001.119843

Journal of Prosthetic Dentistry
Volume 86, Issue 5 , Pages 526-531, November 2001