Abstract 

Statement of problem. Given that meticulous implant prosthodontic procedures are recommended to obtain the best possible intraoral fit, impression materials that are suitable for use with a direct impression technique warrant further investigation. Purpose. This in vitro study compared the amount of torque required to rotate a square impression coping in an impression and evaluated the accuracy of solid implant casts fabricated from different impression materials. Material and methods. Two direct transfer implant impressions were made using 8 impression materials; the torque required to rotate an impression coping in the impressions was calculated. Ten direct transfer implant impressions were made from the master model and poured in a die stone (Resin Rock) for 3 of the 8 initial impression material groups. Linear distances between steel balls placed on each abutment replica were measured with a traveling microscope to determine distortion in the impression procedure for each group. Data were analyzed (P =.05) with ANOVA and Ryan-Einot-Gabriel-Welsch multiple range test for post hoc. Results. With a 1-way ANOVA, average torque values among the material groups differed significantly (P =.001). Polyether (medium consistency) was found to produce the highest overall torque values, followed by addition silicone (high consistency), and then polysulfide (medium consistency). Statistically significant difference was also found among the 3 material groups’ mean absolute cast error using a 1-way ANOVA (P =.0086). Implant casts made from polyether (medium) or addition silicone (high) impressions were significantly more accurate than casts made from polysulfide medium impressions. Conclusion. On the basis of the results of this study, the use of either polyether (medium) or addition silicone (high) impression is recommended for direct implant impressions. (J Prosthet Dent 2000;83:323-31.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 This project was supported in part by funds from The Ohio State University College of Dentistry and presented in part at the 1999 International Association of Dental Research Annual Session as a finalist for the 1999 Arthur R. Frechette Prosthodontic Research Award competition.

☆☆ Reprint requests to: Dr Alvin G. Wee, Section of Restorative Dentistry, Prosthodontics and, Endodontics, College of Dentistry, the Ohio State University, 305 W 12th Ave, Columbus, OH 43210-1241, FAX: 614-292-9422, E-MAIL: Wee.12@osu.edu

PII: S0022-3913(00)70136-3

Journal of Prosthetic Dentistry
Volume 83, Issue 3 , Pages 323-331, March 2000