Journal of Prosthetic Dentistry
Volume 83, Issue 2 , Pages 181-186, February 2000

Resin shear bond strength to porcelain and a base metal alloy using two polymerization schemes☆☆

  • Ibrahim Fevzi Tulunoglu, DDS, MS, PhD

      Affiliations

    • Assistant Professor, Department of Prosthodontics
  • ,
  • Bedri Beydemir, DDS, MS, PhD

      Affiliations

    • Professor, Department of Prosthodontics, Gulhane Military Medical Academy, Center of Dental Sciences

Hacettepe University Faculty of Dentistry, Ankara, Turkey

Abstract 

Statement of problem. Fractures in ceramometal restorations can occur and need to be repaired because replacements are not an economic solution. Purpose. This study evaluated the shear bond strengths of 4 porcelain repair systems (Metabond C&B [ME], Silistor [SI], Clearfil Lustre [CL], and Scotchbond Multipurpose Plus [SQ]) to a base metal alloy and porcelain in relation with the polymerization shrinkage of a visible light-cured composite superstructure and compared with the ceramometal bond strength (Vita VMK 68). Material and methods. Thirty-two samples were prepared for each bonding system: 16 for resin-metal bond strength test, and 16 for resin-porcelain bond strength test. For each group, bonding agent was applied to 8 substructures and the resin superstructure was polymerized onto the bonding agent; and for the remaining 8 specimens, prepolymerized resin superstructures were bonded with bonding agent. All specimens were subjected to 500 cycles between 5°C and 55°C with 20 seconds dwell time. Tests were performed in a mechanical testing machine with a 0.5 mm/min crosshead speed. Results. All materials showed an increase in shear bond strength when prepolymerized resin superstructures were used. However, the effect of polymerization shrinkage of resin superstructure was statistically significant only for CL group (P <.05). The highest metal-resin bond was obtained from ME group with prepolymerized resin superstructures (35.27 ± 2.40 MPa), and the lowest value was obtained for the SI group in which resin superstructures were polymerized in situ (8.71 ± 1.03 MPa). The highest porcelain-resin bond was obtained from SC group with prepolymerized resin superstructures (20.71 ± 1.13 MPa) and the lowest was obtained from SI group (9.99 ± 1.52 MPa). Conclusion. Higher bond strength values were obtained with prepolymerized resin superstructures compared to in situ polymerized superstructures. Metabond C&B provided the best results for both prepolymerized and in situ polymerized resin superstructure preparation techniques at the failures where metal was exposed. The best results in situations in which the fracture is limited into porcelain were obtained with the use of Scotchbond Multipurpose Plus material. However, a variety of in vivo and in vitro tests are required before a final judgment is made. (J Prosthet Dent 2000;83:181-6.)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 15.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Reprint requests to:DR IBRAHIM F. TULUNOGLU, BAHCELIEVLER 15 SOK. 41/1, 06490 ANKARA, TURKEY, FAX: (312)3113741

☆☆ 0022-3913/2000/$12.00 + 0. 10/1/103750

PII: S0022-3913(00)70109-0

Journal of Prosthetic Dentistry
Volume 83, Issue 2 , Pages 181-186, February 2000